Patient Positioning
· Sitting position with hip flexion
· Lateral recumbent with hip flexion
*Avoid neck flexion
Technique Overview
1. Gather supplies and prepare ultrasound equipment.
2. Locate the lumbar spine in transverse plane (probe marker pointed toward the child’s left).
3. Using the spinous processes as reference, mark midline on the skin by advancing the probe cranially and marking a dot on the skin over each spinous process from L5-L2. Connect these dots with a vertical line.
4. In the sagittal plane, identify interspinous spaces
5. Center the interspinous spaces on the screen and mark horizontal lines on the skin at each of the gap levels.
6. Using calipers, estimate the depth to ligamentum flavum / posterior dura.
7. Determine final insertion point(s) at the intersection of the two lines.
8. After landmarking, proceed using your institution’s standard sterile technique and needle insertion protocol. Be mindful that the actual child position should remain unchanged from the time of ultrasound marking.