Indications:
- Evaluate bladder volume prior to catheterization.
- Evaluate bladder volume prior to formal radiology-performed pelvic/gyne or appendicitis ultrasound
- Anuria or oliguria
- Urinary incontinence or problems voiding
- Assessing post-void residual volume
- Dysuria
Equipment
- Ultrasound Machine
- Transducer: Curvilinear Ultrasound Probe or Phased Array Transducer (5-3.5 MHz)
- Preset: Abdominal or Renal
- Ultrasound Gel